Server Room Cooling / Data Center Cooling / Computer Room Cooling / Rack Cooling

The Uptime Institute recently reported that 39% of enterprise data center managers expected that their data centers would run out of cooling capacity in the next 12-24 months and 21% claimed they would run out of cooling capacity in 12-60 months.

Did you know that the power required to cool IT equipment in your data center far exceeds the power required to run that equipment? Overall power in the data center is fast reaching capacity as well and an obvious area that needs to be addressed is implementing cooling best practices where ever possible and utilization of in-row cooling to address hot spots.

To maximize the cooling in your data center a good initial step is an in-depth analysis of your facility to gain a comprehensive understanding of your computer room's ambient conditions, increased understanding of your critical risks, benchmark of performance metrics, and generate a punch list of opportunities for potential cooling improvements. For help in this area we recommend call our VP of Construction and Engineering, Ric Patterson. Ric has built over 6 million square feet of computer rooms worldwide and can help you save money on your next project by offering timely, proactive, creative advice.

Comprehensive Service Contracts
USP&E is your solution for creative, flexible and proactive service and maintenance agreements. Whether you need just one unit installed or require the construction of a complete turnkey internal power network, USP&E's technicians service, repair and maintain all makes and brands of computer room equipment. Consolidating your computer room service contracts with USP&E ensures that any technician dispatched to your facility arrives with the knowledge and experience to maintain your entire system from generators to switchgear to batteries and HVAC.

Please contact us for more information or if you have any questions at 888-515-8773 or email us today at info@uspowerco.com!

Current Inventory:
30 Ton Liebert Upflow

30 Ton Liebert Upflow
1998 with lots of extras


Call to get a quote
5 Ton Liebert Upflow

5 Ton Liebert Upflow
PDQAACU066A-C Air Cooled in great condition


Call to get a quote
5 - 20 TON AIR TECHNOLOGIES SYSTEMS YR 2001 IN MINT CONDITION

5 - 20 TON AIR TECHNOLOGIES SYSTEMS YR 2001 IN MINT CONDITION
MODEL VFS-240-DG-FC-D ** 10 UNITS IN STK!


Call to get a quote
Liebert 2000 10Ton DFlow

Liebert 2000 10Ton DFlow
FH125AUA00, 10Ton 460v, Down Flow yr 2000


Call to get a quote
Liebert Downflow A/C Units

Liebert Downflow A/C Units
77kW, GLYCOOL, 460/3/60, DS077KMA0E1745A, Brand new in original packaging! Four (4) available.


Call to get a quote
Liebert Challenger 3000 A/C

Liebert Challenger 3000 A/C
53,100 BTU/hr, GLYCOOL, 460/60/3, electric reheat, BE061G-AAE16745, Brand new in original packaging!


Call to get a quote
Direct Drive Drycoolers

Direct Drive Drycoolers
460/3/60, DDNT-491A, Brand new in original packaging! Four (4) available.


Call to get a quote
Pump Control

Pump Control
1A23507P1, Brand new in original packaging!


Call to get a quote
Series 610T Liebert UPS

Series 610T Liebert UPS
Three phase UPS, 225KVA / 180kW, U39SA229ACCD154, Brand new in original packaging!


Call to get a quote
Ext. Maintenance Bypass Cabinet

Ext. Maintenance Bypass Cabinet
U36MB22932CC80S, Brand new in original packaging!


Call to get a quote
Ext. Maint. Bypass Transformer Cabinet

Ext. Maint. Bypass Transformer Cabinet
U36TC22932AOC54, Brand new in original packaging!


Call to get a quote
Battery Power Packs

Battery Power Packs
15min/180kW, U36BP225UJBNUUU, Brand new in original packaging! Two (2) available.


Call to get a quote
Liebert FDC

Liebert FDC
AC power system rack, FDC4428GB110959, Brand new in original packaging! Four (4) available.


Call to get a quote
Datacenter AC and UPS Available

Datacenter AC and UPS Available
Two Liebert Datacenter A/C units (VH380A-AAEI6223 Date A-2007 (FH245AUA10 Date K-89) PowerWare BBU (9315-160) Packaged and ready for shipping


Call to get a quote
Liebert CRACs

Liebert CRACs
Two FH200C (10 ton) Two FH248C (12.5 ton)


Call to get a quote
20 Ton Downflow Cracs yr 2003

20 Ton Downflow Cracs yr 2003
We have 20 x 20Ton downflow and upflow units in stock - surplus and used for sale today! Email info@uspowerco.com for a quick quote.


Call to get a quote
20 Ton Upflow Cracs Yr 2001

20 Ton Upflow Cracs Yr 2001
Complete with condensate drains, humidification, reheat, new condensor motors, refurbished, painted like new with Condensor Fans too! Located in Texas.


Call to get a quote

USP&E's Computer Room Data Center Solutions
USP&E specializes in engineering and educational services that enhance data center performance without additional capital investments. These services will help you:

  • Enhance data center reliability
  • Audit data center power efficiencies
  • Optimize your current cooling infrastructure
  • Configure precision cooling to eliminate hot spots
  • Substantially eliminate much of your facility's bypass airflow
  • Facilitate ASHRAE compliance
  • Explore the dynamics of your data center, including cooling requirements and areas for potential improvements
WE ALSO OFFER THE FOLLOWING EQUIPMENT:

Liebert Water-Based Cooling System

Liebert XD Water Based Cooling Module and Racks
The Liebert server rack cooling modules work as a system with Liebert XDP-W Coolant Pumping Unit to supply cooling water to high heat density racks. TheLiebert XDK and Liebert XDR modules offer an alternative to critical applications where the hot aisle/cold aisle approach to cooling is not practical.

Liebert XD Water Pumping Unit
The water-based Liebert XDP-W pumping unit houses the isolating heat exchanger between the Liebert XDR-W or Liebert XDK-W and the building chilled water. It circulates the chilled water to the cooling modules at a temperature always above the actual dew point to prevent condensation.

Dual Power Transfer Switch
The dual power transfer switch is designed to provide continuous 115 V AC power for the enclosure blower and other single corded fans and motor-driven devices. Capable of automatically switching a 5A load during a power failure on one input circuit, the dual power transfer switch can power other single corded fans and motor-driven devices commonly deployed in data centers.

Fan Expansion Kit
Designed for retrofitting various USP&E fan units or to supplement the fan mounting plate and fan roof, modular.

Air Baffle System
The USP&E's Air Baffle System has an air inlet nozzle in the base frame. Cold air is drawn in from below and is routed into the double-walled door. The cold air is then distributed inside the rack with special covers.

DC Fan Mounting Plate
Exceptionally low-noise thanks to FCS speed control, fully fitted. Suitable for USP&E's enclosures with a raised roof (> 20 mm) or 42U Rack's roof plate, vented. It is installed from above. A cable entry is prepared in the rear section of the plate.

Server Fan Assembly
The USP&E server fan assembly takes advantage of the front-to-rear airflow of most servers and allows the user to position the fan assembly in the most critical location within the cabinet. The result is cooler operating equipment, even with very high enclosure heat loads.

Room Air Conditioners
Liebert Air Conditioning Solutions - Liebert precision cooling products provide the precise, year-round cooling required by sensitive electronics while protecting them from the environmental hazards of dust, temperature and humidity. Liebert solutions include standalone, ceiling and wall-mount systems for spot, room and telecom shelter applications, and liquid chilling systems for medical imaging and industrial equipment.

Mini Air Conditioners
Especially developed for small enclosures but can also be used in large enclosures with low heat dissipating requirements. Rittal air conditioners are available in compact roof mount and powerful wall mount versions.